For optimal use, please visit numiqo on your desktop PC!

Analysis type
Measurements
Subgroup (Optional):

How-to

Non-Normal Process Capability Calculator

Surface roughness example data

To calculate process capability for non-normal data, copy your measurements into the table above, choose Non-normal under Analysis type, and select your column under Measurements. Enter the lower specification limit (LSL), upper specification limit (USL), or both. The calculator compares fitted distributions and shows capability indices and estimated defect rates for each model.

Non-normal process capability in three steps: Non-normal selected, the surface roughness column with an upper specification limit of 1.5, and the distribution fit table with the lognormal histogram, QQ plot, Ppk and expected PPM
  1. Choose Non-normal as the analysis type.
  2. Select your measurement column and enter the LSL, the USL, or both.
  3. Compare the distribution fits, then read Ppk and the expected PPM for a plausible model, such as the lognormal distribution here.

Try the surface roughness example

The example contains 80 simulated surface roughness measurements in micrometers, with a right-skewed distribution. Suppose the maximum acceptable roughness is 1.5 micrometers:

  1. Load the example, then choose Non-normal under Analysis type.
  2. Select Surface roughness (micrometers) under Measurements.
  3. Enter 1.5 as USL and leave LSL empty.
  4. Compare the fit table and plots, then read Ppk and the expected PPM above USL for a plausible model.

Supported data and distributions

Use non-normal capability analysis for continuous measurements that a normal distribution does not adequately describe, often because the data are skewed. Use raw continuous measurements, with one observation per row and the column set to metric. Several selected columns are combined into one sample; only combine the same characteristic, units, and process conditions. Missing and invalid cells are excluded.

The calculator fits Weibull, lognormal, exponential, gamma, logistic, and largest extreme value distributions, with normal as a reference. The first four require strictly positive measurements. Each distribution is fitted automatically and reported separately. Subgroups are ignored in this analysis; results describe overall performance rather than within-subgroup Cp/Cpk.

Which distribution fits my data?

The fit table shows the estimated parameters, Anderson-Darling statistic (AD), and p-value. A p-value below 0.05 is evidence against that model; a higher value does not prove it is correct. Do not choose solely by the largest p-value. Check each histogram and QQ plot, especially the tails, and whether the model makes sense for your process. Tail fit affects predicted defect rates.

If none fits adequately, investigate unusual observations or mixed process conditions before relying on the estimates. If the normal model fits, the normal process capability analysis also provides within-process indices and confidence intervals.

Capability indices and defect rates

The calculator uses fitted probabilities at the specification limits, converted to normal Z-scores, to calculate overall capability for each distribution:

Result Meaning
Pp Capability across the specification window; requires both limits.
PPL / PPU Capability relative to the lower / upper specification limit.
Ppk The smaller of PPL and PPU, or the available side for a single limit.

Observed Performance reports the measured proportion outside the limits as parts per million (PPM). Exp. Overall Performance estimates PPM from each fitted model. Higher Ppk indicates less predicted nonconformance on the limiting side, provided the model is credible. Zero observed defects does not imply zero future defects. At least one specification limit is needed for capability and PPM results.

Before interpreting capability

Check process stability with an appropriate control chart; a good distribution fit alone does not establish stability. Use specification limits for acceptable output, not control limits. For more background, see the process capability tutorial. For counts of defects or defective units, see the attribute capability instructions.

Cite numiqo: numiqo Team (2026). numiqo: Online Statistics Calculator. numiqo e.U. Graz, Austria. URL https://numiqo.com